• Slump Cone Test Set for Concrete
  • Slump Cone Test Set for Concrete
  • Slump Cone Test Set for Concrete
  • Slump Cone Test Set for Concrete
  • Slump Cone Test Set for Concrete
  • Slump Cone Test Set for Concrete

Slump Cone Test Set for Concrete

After-sales Service: Yes
Warranty: One Year
Top Diameter: 100±2mm
Bottom Diameter: 200±2mm
Height: 300±2mm
Tamping Rod Diamter: ф16±0.2mm
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Basic Info.

Model NO.
SCT
Transport Package
Carton Box
Origin
China
HS Code
9031809090
Production Capacity
300set/Month

Product Description

Slump Cone Test Set


Application
It is applicable for doing slump test to plastic concrete which with partical diameter no higher than 40mm and slump within 1cm - 15cm. 

Including
It is including slump cone, funnel, ruler, and tamping rod. 

Technical parameters
Cone top diameter 100mm±2mm
Cone bottom diameter 200mm±2mm
Cone height 300mm±2mm
Cone wall thickness no less than 1.5mm
Tamping rod diameter Φ16±0.2mm
Tamping rod length 600±5mm

Slump Cone Test Set for Concrete
Slump Cone Test Set for Concrete


Test Methods:
1.Before the test, so you should wash outside slump extinguishers, and put it in water wettability of the plate (plate in the water when a piece of plastic mat below). Then step up springboard plate.
2.You test the samples using three separate load the drum height slightly larger than the typical load of the third high cylinder, Ramming rods and the sections on each floor, even planting 208,000 25. You need 208,000 208,000 rod in the soil all the plane to the direction from the edge to the center along the helix. Chap Chap 208,000 to the bottom soil to the bottom; Chap 208,000 other two, and insert the lower layer should be inserted about 20-30mm said. Chap 208,000 to the vertical pressure (except some risk), not shocks. 208,000 inserted in the roof, the load should be higher than the slump of concrete cylinder tube, to keep the process as planting 208,000 Add mixture. When the top after planting 208,000 to 208,000 bar with a saw and roll moves rid of surplus concrete trowel knife used extinguishers rolling mouth Completely cones around the end of the mixture. Slump then immediately brought to the vertical tube, bin in 5S-10S completed make concrete horizontal and torque from the role. Slump extinguishers installed expected from the beginning made the whole process should be completed in the 150S.
3.Yardstick used to sample weight than the vertical distance between the top of the highest point, namely the fresh concrete slump, and the accuracy to 1mm.
4.When the concrete specimens or to shear a landslide occurred, another test should be re-sampling, If this happened the second time, said the poor workability of concrete.
5.When the slump φ220mm fresh concrete, Concrete used to extend the final steel ruler measuring diameter of the largest and smallest diameter, The difference between the two is less than 50mm in diameter under the conditions of use of an arithmetic mean value was as Collapse expansion.








 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2017

Suppliers with verified business licenses

Year of Establishment
2014-07-03
Management System Certification
Others
Import & Export Mode
Have Own Export License