Gold Member Since 2017
Audited Supplier
SHAOXING KARE INSTRUMENT EQUIPMENT CO., LTD.

Curing Room, Cement Curing, Concrete Curing manufacturer / supplier in China, offering Cement Concrete Standard Curing Room Automatic Controller (BYS-II), 0.5 Class Computerized PC Stand Tensile Testing Machine (CXGWE-1000B), Electronic Tensile Testing Machine (CXDL-30) and so on.

(/ )

Supplier Homepage Product cement concrete test equipment Cement Concrete Standard Curing Room Automatic Controller (BYS-II)

Cement Concrete Standard Curing Room Automatic Controller (BYS-II)

FOB Price: Get Latest Price
Min. Order: 1 set
Production Capacity: 30 Sets/Month
Transport Package: Wooden Case
Payment Terms: L/C, T/T, D/P, Western Union
Basic Info
  • Model NO.: BYS-II
  • Usage: Control The Temperature and Humidity
  • HS Code: 9024800000
  • Power Source: AC220V
  • Origin: Zhejiang
Product Description
1. Instruction
BYS type "Cement curing room, concrete curing apparatus" is applicable to each cement factory, the cement products factory and reading construction unit, scientific research, quantity examination unit to control the temperature humidity of the standard maintenance room, have the characteristics of operation convenience, controlling accurate, etc.

2. Construction
"Cement curing room, concrete curing apparatus" constitute of the control machine, the large type negative ion adding humidity machine, the stainless steel and the air-condition four greatest parts. The controlling of the temperature and humidity all are automatic commuted by the intelligence instrument, have no need artificial control.

3. Principle
(1)Temperature control: When the temperature inside of maintenance room higher than the upper limit settle value of the temperature control instrument, control system output the cold signal namely, the control air-condition is outside connected and load and work; Whereas, the temperature lower than the below limit settle value of the temperature control instrument, the host heat namely, when attain the control request recover the constant temperature appearance automatically, like this again and again attain to control purpose.

(2)Humidity control: When the humidity inside of maintenance room lower than the control value, control system output the adding humidity signal, control host add the humidity, after the humidity inside of room attain the request stop the work automatically namely.
operating voltage 220± 10V 
temperature control range 0-50º C 
temperature control accuracy ± 1º C 
humidity control scope > 90% 

Cement Concrete Standard Curing Room Automatic Controller (BYS-II)
Cement Concrete Standard Curing Room Automatic Controller (BYS-II)





 